To compare quiet heat pumps, start with manufacturer sound power figures for the exact models under comparable operating conditions. Then ask what sound pressure the installer predicts at a relevant neighbouring location. The physical position and surrounding surfaces can change what people hear. Source: DESNZ noise review.
Sound power and sound pressure
Sound power describes the source. Sound pressure is the level at a specified point, affected by distance, barriers and nearby reflecting surfaces. A product sheet quoting sound pressure at several metres can look quieter than another sheet quoting sound power, even when the products are similar.
Our guide to heat pump noise levels in dB(A) explains the units and typical figures.
A quote comparison you can reuse
| Ask the installer for | Why it matters |
|---|---|
| Rated sound power and operating condition | Makes the model comparison reproducible |
| Proposed position and orientation | Shows where the sound has to travel |
| Predicted level at the relevant assessment point | Links the product to the property |
| Output in any reduced-noise mode | Helps check whether quiet operation also meets heat demand |
The government review found noise complaints appeared relatively infrequent in the evidence available. Siting and proximity featured in the cases studied. Use the applicable planning rules and current assessment standard for the property’s location. Sources: Noise evidence and England planning legislation.
Which model should lead a shortlist?
Compare similar capacities, check the conditions in the datasheets and ask the installer to complete the site assessment for each viable location. A universal brand ranking would require comparable sound data and equivalent installations. In practice the right comparison is between complete designs for the same property.
If a working heat pump has become louder, our guide to a heat pump making noise separates normal sounds from warning signs, and the best location for a heat pump covers siting.