Mitsubishi Ecodan Heat Pump L6 & P6 Error: Freeze Protection Meaning, Causes & Fixes

Mitsubishi Ecodan freeze & defrost faults guide tile: a Mitsubishi Ecodan outdoor unit on gravel beside a timber-clad house
Myles Robinson
Heating and renewables expert
Updated

Get a cover plan here

L6 and P6 on a Mitsubishi Ecodan heat pump are freeze protection codes: L6 protects the circulating water and P6 protects the plate heat exchanger. Mitsubishi's checks are water leakage, strainer blockage and the circulation pump, plus the refrigerant amount for P6. A frozen Ecodan that repeats either code needs an engineer.

At a glance

Get a cover plan here >

  • L6 on a Mitsubishi Electric Ecodan means “Circulation water freeze protection”; P6 means “Anti-freeze protection of plate heat exchanger”. Both come from the FTC flow temperature controller’s error list.
  • Mitsubishi’s action for L6 is the same as for L3: check for water leakage, strainer blockage and the circulation pump. P6 adds a check of the refrigerant amount.
  • Errors are cleared on the Ecodan main remote controller by pressing F4 (RESET) then F3 (Yes); “Please Wait” can then show for up to six minutes.
  • Mitsubishi warns that when the system is switched off or the power is disconnected, the indoor unit protection functions, including the freeze stat function, will not operate.
  • The freeze stat function is a service setting with an outdoor ambient threshold of 3 to 20 °C (default 5 °C) and a fixed flow temperature of 20 °C; L6 repeating after cooling means that threshold is set too low.
  • The main remote controller shows a “Defrosting” icon under the heat pump symbol while the outdoor unit is clearing frost.

What does L6 or P6 mean on a Mitsubishi Ecodan heat pump?

L6 means the FTC controller in a Mitsubishi Electric Ecodan has activated circulation water freeze protection: the water moving round the primary circuit was cold enough that the controller stepped in to stop it freezing. P6 means the anti-freeze protection of the plate heat exchanger has triggered; the plate heat exchanger is where refrigerant from the outdoor unit heats the water in the indoor unit, and it is the part most at risk if water stops moving.

Mitsubishi’s installation manual for the FTC flow temperature controller (PAC-IF071B-E, IF072B-E and IF073B-E) gives L6 the instruction “See Action for L3”, and the L3 action is a three-item check: water leakage, strainer blockage and water circulation pump function. P6 carries the same instruction plus “Check for correct amount of refrigerant”, which is the only point where the refrigerant side enters the picture.

On the Ecodan main remote controller the code appears on screen with the FTC’s description. If the heat pump has stopped altogether rather than showing a code, start with our guide to a Heat Pump Not Working questions answered; every other Ecodan code is explained in our Mitsubishi Ecodan error codes guide.

Is ice on a Mitsubishi Ecodan heat pump normal?

Frost on the outdoor coil of an Ecodan is normal in cold, damp conditions, and the main remote controller tells you when the unit is dealing with it: a “Defrosting” icon appears under the heat pump symbol on the main screen. L6 and P6 are not part of that process. They belong to the water in the indoor unit and the primary circuit, which should stay well above freezing whenever the system is powered and the pump is running.

Mitsubishi’s outdoor unit installation manual notes that the outdoor unit produces condensate during heating and must have drainage, and that performance “can be significantly reduced” if the unit is covered with snow. A snow-buried PUHZ outdoor unit pulls less heat from the air, the water in the indoor unit cools, and a marginal flow problem turns into an L6.

Heavy ice that the defrost cannot clear is a separate fault; our guide to a Guide to Heat Pump Frozen Outside Unit shows what it looks like and how it differs from a water-side freeze protection code.

How does the Mitsubishi Ecodan defrost cycle work?

The Ecodan outdoor unit defrosts by reversing its refrigerant circuit so the outdoor coil warms up and melts its frost, drawing that heat from the primary water. The FTC shows the “Defrosting” icon for the duration. The FTC manual does not describe what happens to the fan or how long a defrost runs, so the fan pause and burst of steam that owners notice are general heat pump behaviour; our guide to the Guide to Heat Pump Defrost Cycle covers it.

The water-side protection is where Mitsubishi is specific. The freeze stat function is set in the FTC service menu with an outdoor ambient threshold adjustable from 3 to 20 °C, default 5 °C, and a fixed flow temperature of 20 °C; entering two asterisks disables it. Below the threshold the FTC runs the system to hold the water at 20 °C. The manual’s warning is blunt: when the system is switched off or the power supply is disconnected, the indoor unit protection functions, including the freeze stat function, will not operate.

That is why an Ecodan should never be isolated in a frost to “clear” a code, and why the manual’s troubleshooting item for L6 repeating after cooling is to raise the freeze stat threshold rather than to switch anything off.

Why has my Mitsubishi Ecodan shown L6 or P6?

L6 and P6 appear when cold water meets weak flow. The FTC manual’s checks are the starting point, and the table below pairs them with the companion codes an engineer looks for in the log.

Symptom Ecodan code Cause Who acts
Code on the main remote controller, heating paused L6 Circulation water freeze protection; FTC checks: water leakage, strainer blockage, circulation pump Owner checks pressure and valves, engineer for strainer and pump
Code with poor heat, possibly in any weather P6 Plate heat exchanger anti-freeze protection; same checks plus refrigerant amount Engineer, including the refrigerant check
Low flow warning L9 Low primary circuit flow rate detected by the flow sensor or flow switch; the manual warns the pump valves may be hot Engineer
Flow outside the outdoor unit’s range LP Out of water flow rate range for the outdoor heat pump unit Engineer
High pressure trip LB Reduced heating circuit flow or a clogged plate heat exchanger Engineer
No communication with outdoor unit E6 to EF FTC to outdoor unit communication; check the outdoor unit has not been turned off Owner checks the isolator, then engineer
Outdoor unit fault U, F or A codes Outdoor unit failure; refer to the outdoor unit service manual Engineer

Low pressure sits behind many of these, because a primary circuit that has lost water loses flow through the strainer and plate heat exchanger first. If your gauge is low, read our guide to Mitsubishi Ecodan low pressure before resetting anything.

How do I clear a Mitsubishi Ecodan freeze fault safely?

Mitsubishi gives owners a reset, so these checks end with it. Do them in order and stop at the casing of both units.

  1. Note the code. Write down L6 or P6 and any companion code, with the time. The FTC keeps an error history the engineer can read.
  2. Leave the power on. The freeze stat function and the other indoor unit protections only run while the system is powered, per the FTC manual.
  3. Check the outdoor unit is on. E6 to EF with L6 usually means someone switched the outdoor isolator off. Clear snow from the PUHZ unit from outside and make sure condensate can drain.
  4. Check pressure and valves. Confirm the primary circuit pressure is in the range your installer set and that radiator, zone and isolation valves are open, so water can move through the plate heat exchanger.
  5. Look for leaks. Water leakage is the first item in Mitsubishi’s L3 check list. A damp patch under the indoor unit or cylinder is a reason to call rather than reset.
  6. Reset once. On the main remote controller press F4 (RESET), then F3 (Yes). “Please Wait” may show for up to six minutes. If the code returns, book an engineer.

Do not remove the panels on the Ecodan indoor or outdoor unit, do not chip ice from the coil or pour hot water on it, and never touch the refrigerant pipework.

When to call an engineer

Call an engineer if L6 or P6 returns after one F4 reset, if P6 appears at all, if L6 keeps coming back after the system has run in cooling mode, if L9 or LP shows with it, or if you find water leaking from the indoor unit. Call straight away if the house is losing heat or hot water has stopped in freezing weather, or if the pressure gauge keeps falling.

An engineer will clean the strainer, test the circulation pump, check for leaks, measure the primary flow rate against the figure for your outdoor unit, and review the freeze stat setting in the service menu. For P6 the refrigerant charge is checked, which only a qualified engineer may do.

UK Heat Pump Servicing provides annual servicing, fault diagnosis and repair, cover plans and new installations for heat pump owners across England, Scotland and Wales. See our Mitsubishi Electric heat pump servicing and repairs page, book a book a repair, compare breakdown cover and annual servicing or find the where we work.

How can I stop L6 and P6 coming back?

L6 and P6 are prevented by keeping primary water moving and warm: a clean strainer, a healthy pump, correct pressure, no leaks and the freeze stat function left enabled at a sensible threshold. Those are exactly the items checked at an annual service, and our article on More on why heat pump servicing is so important explains how a blocked strainer in November becomes an L6 in January.

Outside, keep the PUHZ unit clear of snow and give its condensate somewhere to drain, as Mitsubishi’s outdoor unit manual requires. Keep the outdoor isolator on all winter. Our guide to More on do heat pumps work in cold weather explains why steady running protects the system, and if you want winter faults covered, read whether Is Heat Pump Cover Worth It questions answered. For a broader view of the range, see our Mitsubishi Ecodan Heat Pump Review explained.

Frequently asked questions

Will my Ecodan still heat the house with L6 showing?

Not reliably. Freeze protection puts the system’s safety first, so heating output drops or pauses while the code is active. Once the FTC is reset and water is moving the heating returns, but if the strainer or pump problem behind L6 remains the code will come back on the next cold night. Have the cause fixed rather than living with resets.

Can I change the Ecodan freeze stat setting myself?

The freeze stat function lives in the FTC service menu, with an outdoor ambient threshold of 3 to 20 °C and a default of 5 °C. Mitsubishi’s fix for L6 repeating after cooling is to adjust that threshold, but it is a service setting and the wrong value leaves the system unprotected, so ask an engineer to change it.

Why does L3 sometimes show while the system is being filled?

Mitsubishi notes that the L3 error code may display during filling of the primary circuit, and tells the installer to complete filling and then reset. Because L6 shares the L3 checks, a code that appears straight after a top-up or a repair is often just air and low flow during filling rather than a fault.

Is it normal for my Ecodan to go to hot water after a power cut?

Yes. The FTC manual lists returning to domestic hot water mode at power recovery as normal operation, because the controller runs the mode with the higher priority first. “Please Wait” may also show for up to six minutes while it restarts. Neither is a fault, and neither needs a reset.

Does P6 mean my Ecodan has a refrigerant leak?

Not necessarily. P6 carries the same water-side checks as L6, and a blocked strainer or weak pump is the commoner cause. The manual adds a check of the refrigerant amount because low charge makes the plate heat exchanger run colder. Only an engineer can measure the charge and find a leak.

Sources and further reading: Mitsubishi Electric Flow Temp. Controller PAC-IF071B-E, PAC-IF072B-E, PAC-IF073B-E and PAC-SIF051B-E Installation Manual, BH79D843H06, error code list, service menu and troubleshooting sections (library.mitsubishielectric.co.uk); Mitsubishi Electric Ecodan PUHZ-W50VHA2 outdoor unit installation manual, drainage and snow notes (read as a manualslib copy, manualslib.com).