At a glance
- An Octopus Cosy heat pump has no numbered fault codes. A heat pump fault shows as a flashing red light on the Cosy Hub, and Octopus’s instruction is to call 0808 196 6842 or email aftercare@octopus.energy.
- Octopus says a thin layer of ice on the outdoor unit is normal and that Cosy briefly switches into defrost mode to clear it, most often between 7 °C and minus 5 °C.
- Octopus’s rule on ice is “don’t interfere”, and its threshold for calling the installer is ice that continues to build up on or inside the heat pump.
- Hush Mode limits the compressor and fan to 60 percent, and Octopus says it needs to be turned off in the colder months.
- Heating Off mode still holds a 7 °C frost protection setpoint, so the Cosy should stay powered through a cold spell.
- Octopus’s pressure guidance is to top the system back up to 1.5 bar when it drops.
Why has my Octopus Cosy heat pump frozen?
An Octopus Cosy freezes when frost on the outdoor unit’s evaporator, the finned coil at the back, builds faster than the defrost cycle clears it. Octopus does not publish fault codes for this or anything else, so what you see is physical: ice that stays, rooms that stop warming, and if the heat pump reports a fault, a flashing red light on the Cosy Hub. Octopus’s user manual gives one instruction for that light: contact aftercare on 0808 196 6842 or at aftercare@octopus.energy.
The manual draws a clear line between normal and not. A thin layer of ice that Cosy clears by briefly switching into defrost mode is expected. Ice that “continues to build up on or inside your heat pump” is the trigger to call your installer, because there could be a problem. The older “Get to know your Cosy” guide explains some of what sits behind that: a blocked evaporator sensor that reacts to leaves or debris blown into the unit, a fan tachometer, and a water flow sensor that notifies you if flow becomes restricted, any of which can put the unit into a safe error state.
If the Cosy has stopped altogether rather than iced, our guide to a heat pump not working covers the first checks, and our guide to Octopus Cosy error codes and fault lights decodes every Hub and Pod light.
Is ice on an Octopus Cosy heat pump normal?
Yes, within limits that Octopus spells out. The Cosy user manual says a thin layer of ice can build up on the outdoor unit, that Cosy briefly switches into defrost mode to clear it, and that heating may pause for a short time while it does. It also says the unit may seem louder in colder weather or during the hot water cycle, and that this is normal.
Water around the base is part of the same picture. Octopus says it is normal for heat pumps to create water, that melt water drains through the same drain used for all the water created during defrosting, and that water, snow and ice cannot enter the inner workings. If water is not draining, the manual’s advice is to check for obvious debris or blockage that can be carefully cleared away, then contact your installer.
The manual’s safety wording is unusually direct: “If there’s ice build-up on your heat pump, don’t interfere as this can damage the system.” For a brand-neutral picture of frost against a fault, see our guide to a Heat Pump Frozen Outside Unit.
How does the Octopus Cosy defrost cycle work?
The Cosy defrosts by reversing its refrigerant circuit for a short period so the evaporator warms and sheds its ice, drawing the heat from the water in your heating system. Octopus gives owners the useful detail of when to expect it: defrosts are most common between 7 °C and minus 5 °C, because above 7 °C the evaporator usually is not below zero and below minus 5 °C the air is usually too dry to frost it. On a damp day at 3 °C a Cosy will defrost often, and that is correct behaviour.
Octopus’s documents do not describe steam or fan behaviour during a defrost, so those are general heat pump observations; our guide to the Heat Pump Defrost Cycle explains them. What Octopus does document is the plumbing that supports defrost: a volumiser that provides extra water for defrost cycles, and a 7 °C frost protection setpoint that Heating Off mode still holds. The manual also defines short cycling as five or more start-ups in a 60 minute period, which an engineer will look for if a system seems to defrost endlessly.
Hush Mode is the setting most likely to catch owners out in winter. It limits the compressor speed and fan speed to 60 percent, and Octopus states plainly that in the colder months you will need to turn it off.
What does a frozen Cosy look like, and who should act?
With no codes to read, the Cosy tells you about icing through lights and symptoms. The table maps Octopus’s own wording to the likely cause and the right person to deal with it.
| What you see | Cosy signal | Likely cause | Who acts |
|---|---|---|---|
| Thin ice on the outdoor unit that clears | None | Normal defrost between 7 °C and minus 5 °C | Nobody |
| Ice that continues to build on or inside the unit | None, or Hub flashing red | Blocked airflow, debris on the evaporator sensor, restricted water flow, or a refrigerant problem | Owner clears debris, then installer or Octopus aftercare |
| Hub flashing red | Heat pump fault | Any fault the unit reports, including a safe error state after a sensor trip | Octopus aftercare on 0808 196 6842 |
| Rooms cool, unit running quietly | Hush Mode on | Output limited to 60 percent | Owner turns Hush Mode off in the app |
| Puddle under the unit, nothing draining | None | Blocked drain refreezing at the base | Owner clears visible debris, then installer |
| Hub solid yellow after a power cut | Lost WiFi | Router still rebooting; the heat pump keeps running | Owner waits for reconnection |
| Hissing from the outdoor unit | None | Possible refrigerant leak | Stay away and call the Octopus helpline |
Low pressure is behind many flow problems. Octopus’s own figure is to top the system back up to 1.5 bar, and our guide to Octopus Cosy Heat Pump Low Pressure explained explains how and when.
How do I clear a Cosy freeze safely?
Octopus’s guidance for owners stops well short of touching the unit, and these steps follow it.
- Check the Hub light. Flashing red means a heat pump fault: note the time and call aftercare. Solid yellow or solid red relate to WiFi and Pods, not the heat pump.
- Keep the Cosy switched on. Octopus’s troubleshooting checks are that the units are switched on, the app is connecting and the circuit breaker has not tripped. Heating Off still holds 7 °C frost protection only while the unit has power.
- Turn Hush Mode off. In the app, confirm Hush Mode is off for the winter so the unit can run at full speed and defrost properly.
- Clear the surroundings. Octopus asks you to keep the area around the unit clear of garden furniture, pots, leaves and snow. The manual allows a soft brush on the evaporator; it does not allow water, tools or removing the covers or fan cap.
- Check the drain and the pressure. Clear any obvious debris from the drain by hand and read the system pressure, topping up to 1.5 bar if it has dropped.
- Do not reset. Octopus publishes no reset procedure, and a flashing red Hub is a call to aftercare rather than something to power cycle.
Never chip at ice, pour hot water over the unit or open its covers. Octopus’s safety section says leaking refrigerant can cause severe burns and frostbite: if you smell gas or hear hissing, stay well away and contact the helpline immediately.
When to call an engineer
Call Octopus aftercare or your installer as soon as ice keeps building on or inside the Cosy, which is Octopus’s own threshold, or whenever the Hub flashes red. Call straight away if water is not draining, if the casing or evaporator is damaged, if rooms stay cold after you have checked Pod placement, setpoints, radiator valves, pressure and Hush Mode, or if you suspect a refrigerant leak.
Most Cosy owners are within an Octopus aftercare arrangement, so that is the first call. Where cover has ended, where you want an independent opinion on ice that keeps returning, or where a refrigerant fault is suspected, an engineer can test airflow, flow, pressure, the defrost and the refrigerant charge in one visit.
UK Heat Pump Servicing provides annual servicing, fault diagnosis and repair, cover plans and new installations for heat pump owners across England, Scotland and Wales. Book an independent our repair service, compare annual cover with servicing included for when aftercare ends, or check the engineers across England, Scotland and Wales.
How can I stop my Cosy icing up again?
Keeping a Cosy clear through winter follows Octopus’s own list: keep the area around the unit free of furniture, pots, leaves and snow, keep the drain clear, leave Hush Mode off in the colder months and hold the pressure at 1.5 bar. A yearly check of the evaporator, drain, pressure and defrost catches the rest, and our article on Why Heat Pump Servicing Is So Important explains what a service should cover once your installation support period is over.
Siting is the other half. A Cosy pushed into a corner behind bins, or sitting where a gutter drips onto it, will ice sooner than one with open air around it. Our guide to Do Heat Pumps Work in Cold Weather explains why a heat pump works best left running steadily rather than switched on and off, and if you want repairs covered once aftercare has finished, read whether Is Heat Pump Cover Worth It for a Cosy.
Frequently asked questions
Can Hush Mode leave rooms cold in a freeze?
Yes. Octopus says Hush Mode limits the compressor and fan to 60 percent, which may not keep up on the coldest days and gives the unit less capacity to defrost. The manual states that in the colder months you will need to turn it off. If rooms are cool in a cold snap, check Hush Mode in the app before assuming a fault.
What should I tell Octopus aftercare when I call?
Tell them the Hub light pattern, when the ice started, whether it clears between defrosts and whether water is draining. A photo of the outdoor unit helps, as does a note of any unusual noise. Octopus says its aftercare line runs 9 am to 5 pm Monday to Thursday and 9 am to 4 pm on Friday, so for a cold home outside those hours have an independent engineer’s number too.
Should I cover my Cosy outdoor unit in winter?
No. The Cosy needs open air through the evaporator to heat and to defrost, and Octopus’s guidance is to keep the area around it clear rather than to shelter it. The manual also says never to open the covers or the fan cap, so any canopy would be an installer question, not a DIY job.
Why is there a puddle under my Cosy on a cold morning?
Because it has been defrosting. Octopus says it is normal for heat pumps to create water and that defrost melt water leaves through the unit’s drain. A puddle that freezes into a sheet, or water that is clearly not draining, is the point at which Octopus asks you to clear obvious debris and then contact your installer.
Which Cosy models does this apply to?
The Cosy user manual covers the Cosy series, including the Cosy 6, which is about 150 mm shorter than the Cosy 9 and Cosy 12. All share the Hub and Pod controls and the same defrost guidance, so the lights, the 7 °C to minus 5 °C defrost window and the aftercare contact are the same across the range.
Sources and further reading: Octopus Energy, Cosy User Manual version 26.1, sections on defrost, troubleshooting, Hub and Pod lights and safety (octopus.energy); Octopus Energy, Get to know your Cosy heat pump, version 20.2 (octopus.energy); Octopus Energy heat pump support page (octopus.energy).