Please note: this guide is general advice only. Samsung updates its manuals from time to time, so check the one for your model before you do anything. Nothing in this guide asks you to open the unit, touch wiring or do anything that could put you at risk or affect your warranty.
E911 on a Samsung EHS heat pump means the unit has told its water pump to run, but the flow switch can’t see enough water moving through the system. Samsung calls it a “Flow Switch Open Error”. The heat pump stops heating to protect itself, and in most homes the cause is somewhere in the water side of the system rather than the outdoor unit.
The good news is that a lot of E911 faults come down to simple things like closed radiator valves, air in the pipes or a clogged filter. The less good news is that some causes, such as a tired circulation pump or a faulty flow sensor, need an engineer. Below we explain what the code means, what you can safely check, and when it’s time to book someone in.
What does E911 mean on a Samsung heat pump?
E911 means the water pump is running but the flow switch is reporting too little flow. Your heat pump needs a steady stream of water passing through it to move heat into your home. If that flow drops below what the unit expects, it shuts down so it doesn’t overheat or damage its own heat exchanger.
Samsung sets a minimum flow for each model. On units of 9 kW or below it’s 7 litres per minute, and on larger units it’s 12 litres per minute. If flow stays under that for more than a few seconds, the unit stops. You won’t be able to measure that yourself, but it explains why the heat pump is so quick to react when something restricts the flow.
E911 has two related codes that sometimes show up alongside it:
| Code | Samsung’s name for it | What it means in plain English |
|---|---|---|
| E911 | Flow Switch Open Error | The pump is running but not enough water is moving |
| E912 | Flow Switch Close Error | The switch says water is flowing when the pump is meant to be off |
| E913 | Repeated flow switch error | The flow fault has been picked up six times and the unit stops trying to restart |
If you’re seeing E911 and E912 together, or the system has gone on to show E913, that’s a strong sign the fault isn’t going to clear on its own. For the full list of Samsung codes, see our Samsung heat pump error codes guide.
Is it safe to keep using the heat pump when E911 shows?
Yes, E911 isn’t dangerous in itself. It’s a protection code, so the heat pump has already done the sensible thing and stopped. There’s no risk of fire or electric shock from the code alone.
The problem is practical. While E911 is active you’ll lose heating, hot water, or both. In very cold weather, a system that’s been off for a long time can also be at risk of freezing, because Samsung’s frost protection needs water moving through the unit to work properly. If it’s below freezing outside, don’t leave an E911 fault sitting for days. Our guide to Samsung E908 and E909 freeze protection codes explains more about that side of things.
What causes E911 on a Samsung heat pump?
The most common causes are air in the system, low water pressure, a blocked filter and closed valves. Less often, the circulation pump or the flow sensor itself is at fault. Here’s how they compare:
| Cause | What you might notice | Who should fix it |
|---|---|---|
| Radiator valves or TRVs turned down | Code appears during heating, often after you’ve turned rooms down | You can check this |
| Low system pressure | Pressure gauge reading lower than usual | You can check it; an engineer should find out why it dropped |
| Air trapped in the pipes | Gurgling, cold patches on radiators, code after recent work on the system | Engineer |
| Blocked strainer or magnetic filter | Code builds up over weeks, heating feels weaker before it stops | Engineer |
| Isolation valves left part-closed | Code starts straight after a service, repair or new radiator | Engineer |
| Circulation pump wearing out or set too low | Humming, pump running hot, flow slowly getting worse | Engineer |
| Faulty flow sensor or loose wiring | Code comes and goes with no pattern, pressure and radiators look fine | Engineer |
| Diverter valve sticking | Code only on hot water or only on heating | Engineer |
| Pipework or design problems | Code since the day it was fitted, often when several zones close at once | Engineer or original installer |
Closed radiator valves
This one catches out a lot of people. Heat pumps are designed to run with most of the radiators or underfloor loops open. If you turn the thermostatic valves down in several rooms at once, there may not be enough open pipework for the water to move through. The pump runs, the flow switch sees very little, and up comes E911.
Low pressure and air
When pressure drops, air can get into the system. Air pockets don’t flow like water, and they can sit right where the flow switch is reading. Pressure loss usually has a cause of its own, such as a small leak or a pressure relief valve that’s letting by. Our guide to heat pump pressure loss covers that in more detail, and our Samsung E911 and E912 low pressure guide explains how pressure links to these codes.
A blocked filter
Most heat pump systems have a strainer or magnetic filter on the return pipe. Over time it collects sludge, rust and bits of debris. As it fills up, flow drops a little at a time until the heat pump finally trips. If your system hasn’t been serviced in a while, this is one of the first things we’d look at.
Does it matter if E911 shows during heating or hot water?
Yes, it’s one of the most useful clues you can give an engineer. When the code appears tells you which part of the system is struggling.
| When E911 shows | Where the problem is likely to be |
|---|---|
| Only during heating | Radiators, TRVs, zone valves or underfloor manifolds |
| Only during hot water | The diverter valve or the coil inside the hot water cylinder |
| During both | Something shared by both circuits, such as the pump, filter, air in the system or the flow sensor |
Make a note of when it happens before you call anyone. It can save time on the visit and help the engineer bring the right parts.
What can you safely check yourself?
You can check the pressure, open up your radiator valves and try a single reset. Anything beyond that should be left to a qualified heat pump engineer. Here’s a safe order to work through:
- Look at the pressure gauge. If you have one you can see, compare it with the figure your installer gave you. Samsung’s manual says the system should be filled to between 1.5 and 2.0 bar and should stay at around 1.0 bar or above. If yours is well below what it normally reads, that’s likely part of the problem.
- Open your radiator valves. If the code shows during heating, turn a few TRVs back up, especially in rooms you’ve recently turned down. Then see whether the heating starts again.
- Check for obvious leaks. Our guide to heat pump leaks shows where to look. Check under radiators, around the indoor unit and along any pipes you can see. Don’t take anything apart.
- Reset once. Turn the system off at the controller, wait a few minutes and turn it back on. If E911 comes straight back, stop there.
- Write down what you’ve seen. When the code shows, what the pressure reads and whether anything changed recently.
Please don’t top up the pressure yourself unless your installer has shown you how and you’re confident doing it. Don’t try to bleed the pump, open the indoor or outdoor unit, or reset the system again and again. Repeated resets can push the unit into E913, and any work on the refrigerant side must only be done by an F-Gas certified engineer.
What will an engineer check to fix E911?
An engineer will look at the whole water circuit, not just the heat pump. A typical E911 visit includes:
- Checking and correcting the system pressure, then finding out why it dropped
- Purging air from the system and the heat pump itself
- Taking out and cleaning the strainer or magnetic filter
- Making sure every isolation valve is fully open
- Testing the circulation pump and checking its speed setting
- Testing the flow sensor and its wiring
- Checking the diverter valve if the code is linked to hot water
- Reading the error history on the controller to see how often E911 has appeared
If the system has had E911 since it was installed, the engineer may also look at pipe sizes and whether the system needs a buffer tank or a bypass. That’s more of a design issue than a fault, and it’s worth raising with your original installer.
Why does E911 keep coming back after a reset?
E911 usually comes back because the reset clears the code but not the cause. If flow is borderline, the heat pump might run happily for a few hours and then trip again as soon as conditions change.
Common reasons it keeps returning:
- Air moving around the system and settling near the flow switch again
- A filter that’s partly blocked, so flow is fine at low demand but not at full output
- A pump that’s getting weaker with age
- Rooms or zones closing at the same time, leaving too few open circuits
- A flow sensor giving unreliable readings
If you’ve had E911 more than twice in a week, book an engineer rather than living with it. Running a heat pump with poor flow makes it work harder, which pushes up your electricity bills and puts extra wear on parts.
How much does it cost to fix E911?
Most E911 faults are fixed in a single visit, and the cost depends on whether parts are needed. As a rough guide:
| Repair | Rough cost |
|---|---|
| Diagnostic visit, pressure top-up and air purge | £90 to £180 |
| Filter clean during a service | Usually included in an annual service |
| Replacement flow sensor | £150 to £350 fitted |
| Replacement circulation pump | £250 to £600 fitted |
| Replacement diverter valve | £200 to £450 fitted |
Prices vary by area, model and how easy the parts are to reach. Our heat pump servicing cost guide gives more detail on what to expect.
How can you stop E911 happening again?
The best way to prevent E911 is a yearly service and keeping enough of your heating circuit open. A few simple habits help a lot:
- Have the heat pump serviced every year so the filter is cleaned and the pressure, pump and flow are checked
- Keep most radiator valves open and let the controller and weather compensation manage the temperature instead
- Glance at the pressure gauge once a month, especially in winter
- Ask your engineer to check the inhibitor level, which helps stop sludge forming
- Get small leaks fixed quickly, before they lead to pressure loss and air
You can see what a full service covers in our heat pump annual service checklist. If your system is full of sludge, our guide to heat pump powerflushing explains when a deeper clean makes sense.
Need help with a Samsung E911 error?
If E911 won’t clear, or it keeps coming back, it’s best to book an engineer early rather than waiting for the heating to stop on a cold night. At UK Heat Pump Servicing, our engineers work on Samsung EHS systems every week, and a service covers the water side, the electrics and the controls, and does not involve opening the refrigerant circuit.
We can diagnose and repair heat pump faults, carry out annual servicing, and offer heat pump care plans so you’re covered all year. You can find out more about our Samsung heat pump servicing or check whether we cover your area.
For Samsung’s own technical details, see the Samsung EHS technical data manual (PDF).
Frequently asked questions
Will E911 affect my Samsung warranty?
No, the code itself won’t affect your warranty. What matters is how it’s fixed. Samsung warranties usually depend on the system being installed and serviced by a qualified engineer, so having the fault repaired properly and keeping your service records up to date protects your cover.
Can a power cut cause E911?
Yes, sometimes. When power comes back, the pump and heat pump restart together, and a pump that’s slow to get going can trigger a one-off E911. If it clears after one reset and doesn’t return, it was probably a blip. If it keeps happening after power cuts, the pump may be getting weak.
Is E911 the same on Samsung Gen 6, HTQ and R290 models?
Yes, E911 means a flow switch error across Samsung’s EHS range. The exact flow figures and settings can differ between models, so your engineer will check the manual for your specific unit.
Why does E911 show up first thing in the morning?
Mornings are when the heat pump often ramps up from a lower overnight setting. If flow is only just enough at low output, the jump in demand can tip it over. Cold water in the pipes is also thicker and can be harder to move, which makes a borderline flow problem show up more.
Can I still use my immersion heater while E911 is showing?
If your hot water cylinder has an immersion heater, you can usually still use it for hot water while you wait for an engineer. It won’t help with heating, and it costs more to run, so treat it as a short-term backup.